This article gives you information about a ControlSpace error which only appears with versions 5.1.1 and 5.2.
When using ControlSpace Designer versions greater than 5.8.2, you will not have this issue.
Symptom
If a design is created in ControlSpace Designer 5.1 or before and then updated to version 5.1.1 or 5.2, recalling a Parameter set via GPI will generate a red power LED.
After a power cycle, it will also throw a error notification:
Relevant Product(s)
- ControlSpace Designer
- ControlSpace ESP DSPs
- ControlSpace EX DSPs
Resolution
To resolve this you can make a "Downgrade" to version 5.1:
- Scan for Devices as soon as the unit has booted
- Upload empty Design File
- Downgrade to CSD 5.1 or below
- Power cycle the unit
- Upload original Design File
- For the EX-440C, EX-1280 or EX-1280C, instead of Step 1-2, you can also Restore the Design to the Factory Design
A better option is to make an "Upgrade" to version 5.8.2 or higher:
- Scan for Devices as soon as the unit has booted
- Upload empty Design File
- Upgrade to CSD 5.8.2 or higher
- Power cycle the unit
- Upload the updated Design File
- For the EX-440C, EX-1280 or EX-1280C, instead of Step 1-2, you can also Restore the Design to the Factory Design